What went wrong? And something you are talking about tutorials available at ansys customer website, is it same as ansys help tutorials or different???? There is not many people who hang around forums for that long. Multi-block grids allow for customization of various regions. navigate here

The "conservative" variables show the actual control volume values, and will not in general, be zero at the wall. Some models require additional numerical accuracy to solve. Search through the file for all the walls and make sure the thickness is not zero - you should not see: (d . 0). Sirius CFD 59,766 views 15:00 Ansys 14 Fluid flow FLUENT 1 - Duration: 14:16.

Floating Point Exception Fluent

Thank you Elisabetta February 7, 2008, 11:00 Re: ERROR: Floating point exception: Overflow #2 Toralf Guest Posts: n/a Hi, that is a common question here. D - диаметр среза сопла.

Наверх 19 февраля, 2013 - 22:57 #11 MaxDamage Понятно. Об этом подумаю позже когда разберусь с созданием материалов (жидкостей и газов). Как оказалось, в опытах how you solved that error??? How do you know?

yay! These describe the general principles of writing a good forum question. Mostly the CFD-mesh deformation is too big and negative elements appear. Divergence Detected In Amg Solver Postprocess both the CFD and solids results in CFX-Post.

If you have any tutorials please give me... Stopped In Routine Fpx: C_fpx_handler CFX-Post also allows for some a posteriori mesh quality calculations. Loading... Where can I find a basic ICEM tutorial?

This page has been accessed 269,312 times. Floating Point Exception C++ For turbulence modeling, a boundary layer thickness of y+max < 1 is recommended to capture the viscous sublayer properly. Postprocessing Why are my results inaccurate? You can also make these changes in the bc file.

Stopped In Routine Fpx: C_fpx_handler

Close the attachments window. Many simple problems can be spotted in a command file by an expert user. Floating Point Exception Fluent Consider why are the residuals high in that region - Is it: Poor quality mesh - the fix is obviously do a better quality mesh A physical instability, such as vortex Floating Point Exception In C Later i intend to use this solution to run my transient case.

Otherwise, the rounded result is returned. :invalid This exception occurs when the result of an operation is ill-defined, such as (/ 0.0 0.0). http://epssecurenet.com/floating-point/floating-point-exception-c.html These are the possible floating point exceptions: :underflow This exception occurs when the result of an operation is too small to be represented as a normalized float in its format. I'm new here in CFX and it seems like I have the same problem you have faced here. On a Windows PC it is not, on Unix it is necessary. Floating Point Exceptions

This means the only work the solver is doing is calculating the mesh motion. The CFD-Online forum has general comments on this issue which everybody should be aware of here. However, discretization errors also depend on grid quality (e.g., aspect ratio, orthogonality, skew). his comment is here If you find the answer please let me know how you resolved the issue.

You want to model it using the model, with the most accurate discretization, with several pressure specified opening boundaries and a complex, curved geometry. Floating Point Exception 8 Doing a simulation which does not include tricky physics, for instance doing a single phase model before introducing the multiphase physics. One-way or two-way FSI coupling.

so that i can check my boundry conditions...

Click "Upload" Your image/attachment should now appear in the attachments window. If you still cannot get the simulation to converge then try running it as a transient simulation. A link to the Ansys Input File is required. 4. Floating Point Exception (core Dumped) Contents 1 CFX-5 1.1 Solver related questions 1.1.1 My steady state solution converges for a while but stops converging before reaching my convergence criteria 1.1.2 How to avoid 6000 - 7000

For details, see Boundary Condition Modeling. NorthWestStem 91,374 views 8:06 Loading more suggestions... A fatal failure of the linear solver could look like this:======================================================================= TIME STEP = 6 SIMULATION TIME = 3.00E+11 CPU SECONDS = 1.05E+02 ---------------------------------------------------------------------- | Equation | Rate | RMS Res weblink The closer the initial condition is to the real flow field the easier it will be for the solver to converge.

Is it possible to write back-up files of a FSI simulation in Ansys 11.0? Category Science & Technology License Standard YouTube License Show more Show less Loading... Imprint: CFDEMresearch GmbH | Industriezeile 35, 4020 Linz, Austria Перейти к основному содержанию Toggle navigation Блог Форум Видео Поиск cae-expert.ru Перед началом работы настоятельно рекомендуем ознакомиться с правилами форума. Форумы Гидродинамика Please tell me how you solved the problem??

Grid Resolution A resolved grid is one in which the solution parameters of interest (e.g., skin friction) no longer change with further refinement. Transient simulations are much slower than steady state simulations so be aware that you will need extra patience. Please try again later. Please feel free to add questions and answers here!

Is double precision required? My resilduals become flat and i do not observe any change in them for long periods. opening - более правдоподобное гран условие, т к никто не запретит воздуху возвращаться в трубу на выходном отверстии. Хочется сделать опыт с реальным газом аргоном.С воздухом 25 С данный расчёт проходит, Sign in 1 Loading...

Is it possible to stop a running FSI simulation in Ansys 11.0? maryam CFX 3 May 18, 2010 07:44 Floating point exception: Overflow? please find your valuable time for me and can you please check it and give me the link of tutorials which are available at ansys customer website??? . Advantages of an unstructured grid Unstructured grids are highly robust and simpler to generate.

This feature is not available right now. If this is successful you should run the final few iterations to convergence with a physical timescale (not local timescale all the way to convergence). See you again Bye Elisabetta February 21, 2008, 07:50 Re: ERROR: Floating point exception: Overflow #10 shehab Guest Posts: n/a Hi Elisabetta : my name is shehab. The tricky part is how do you get "Wall Temperature"?

CFDEM®coupling-PREMIUM Online documentation Version History Citing CFDEM®coupling Benchmarks Training Download For everyone: CFDEM®coupling-PUBLIC 4 way unresolved CFD-DEM Resolved CFD-DEM (immersed boundary) Convective Heat Transfer Highly customizable solvers For industry: CFDEM®coupling-PREMIUM Non-spherical For a two-way simulation: 1. The variable "Velocity" is relative to the local frame of reference. How should I ask my question on the CFX forum to get the best possible answer?